Company Information

* Company
* Name
* Phone

Key Parameters for Compressor inquiry

Suction Pressure

Discharge Pressure

Flow Rate

Cooling Method

Suction Temperature (℃)
Discharge Temperature(℃)
Power Supply(V/HZ)
Control Requirements
Gas Medium
Additional Remarks (You can also send your datasheet to our email)

Hydrogen Chloride Compressor from China Suppliers | High-Quality Factory Equipment for Corrosive Gas Handling

Introducing our specialized equipment designed specifically for handling highly corrosive hydrogen chloride gas. As a leading supplier in China, our factory utilizes advanced corrosion-resistant materials and cutting-edge sealing technologies to ensure ultra-high gas purity and operational safety. This reliable solution is tailored to meet the stringent demands of the electronic industry and high-end chemical sector, making it an essential choice for businesses seeking safety and efficiency in their operations. Trust our expertise as a premier manufacturer in China to deliver the quality and performance you need for your applications

    Advantages of Hydrogen Chloride Diaphragm Compressor
    01

    Absolute Sealing, Safe Zero Leakage

    The static sealing design completely encloses the gas within the diaphragm head chamber without any dynamic sealing points, fundamentally achieving zero leakage of hydrogen chloride gas. This greatly ensures operator safety and environmental friendliness, meeting the most stringent environmental and safety regulations.

    02

    Ultra-High Gas Purity, No Contamination

    During the entire compression process, the process gas only contacts specially treated metal diaphragms and corrosion-resistant flow-wetted components, completely avoiding contamination from lubricating oil or sealing grease. This characteristic makes it ideal equipment for producing electronic-grade high-purity hydrogen chloride (purity > 99.999%) used in semiconductor etching processes, ensuring the quality of end products.

    Key Design Points for Hydrogen Chloride Diaphragm Compressor
    01

    Corrosion-Resistant Materials

    All metal components in contact with hydrogen chloride, including the diaphragm chamber, cylinder head, gas valves, inlet/outlet piping, and flanges, must be made of corrosion-resistant alloys. The standard configuration is SS316L stainless steel, whose addition of molybdenum (Mo) significantly enhances resistance to chloride pitting and stress corrosion cracking (SCC). For applications with extremely high moisture content or harsh operating conditions, evaluation and selection of higher-grade nickel-based alloys are required.

    02

    Diaphragm Reliability

    As the core isolation component, the diaphragm must be made of a special alloy with excellent resistance to hydrogen chloride corrosion and high fatigue strength, such as Inconel 718. Advanced designs such as an embedded diaphragm head should be adopted structurally to simplify the sealing surfaces, reduce potential leakage points, and ensure sufficient cycle life. A diaphragm rupture alarm device must be provided; once the inner diaphragm is damaged, the system can promptly alarm and shut down safely.

    03

    Safety & Monitoring

    The compressor skid integrates a high-efficiency inlet separator to strictly remove liquid water and particulates from the gas. Controlling the inlet moisture content is key to preventing wet corrosion. All exposed parts shall undergo surface anti-corrosion treatment to resist atmospheric corrosion. The system is equipped with comprehensive monitoring of pressure, temperature, and oil pressure, along with interlock shutdown functions to ensure safe operation within set parameters.

    Certificates
    eac
    ce
    iso
    iso2033
    atex
    Model Selection
    Hydrogen Chloride Diaphragm Compressor
    ModelG70Z/G95Z/G110Z/G130Z
    Piston Stroke70mm~130mm
    Maximum Piston Force10KN~30KN
    Maximum Discharge Pressure70Mpa
    Flow Range1~500Nm³/h
    Motor Power2.2KW~30KW
    Crankshaft Speed420rpm
    Cooling MethodWater Cooled/Air Cooled
    HCl Diaphragm Compressor
    ModelG70V/G95V/G130V
    Piston Stroke70mm~130mm
    Maximum Piston Force10KN~30KN
    Maximum Discharge Pressure50Mpa
    Flow Range1~200Nm³/h
    Motor Power2.2KW~30KW
    Crankshaft Speed420rpm
    Cooling MethodWater-cooled / Air-cooled
    HCl Compressor
    ModelG110L/G130L
    Piston Stroke110mm~130mm
    Maximum Piston Force20KN~40KN
    Maximum Discharge Pressure100Mpa
    Flow Range10~1000Nm³/h
    Motor Power7.5KW~90KW
    Crankshaft Speed420rpm
    Cooling MethodWater-cooled / Air-cooled
    High Purity HCl Compressor
    ModelG110D/G130D/G150D/G180D/G182D/G210D
    Piston Stroke110mm~210mm
    Maximum Piston Force20KN~160KN
    Maximum Discharge Pressure100Mpa
    Flow Range30~2000Nm³/h
    Motor Power22KW~200KW
    Crankshaft Speed420rpm
    Cooling MethodWater-cooled / Air-cooled
    Model Parameter Guide (Example: GZ-5/0.5-8)
    G Diaphragm type compressor
    Z Piston stroke 70mm
    5 Flow (Nm³/h)
    0.5 Inlet pressure (barg)
    8 Outlet pressure (barg)
    No. Model Cooling water (L/h) Flow (Nm³/h) Inlet pressure (MPa) Outlet pressure (MPa) Dimensions L×W×H (≈mm) Weight (≈kg) Motor Power (kW)
    1 GZ-5/0.5-8 500 5 0.05 0.8 1400×740×1240 700 2.2
    2 GZ-14/39-45 500 14 3.9 4.5 1000×460×1100 700 2.2
    3 GZ-60/30-40 500 60 3 4 1400×800×1300 750 3
    4 GV-11/1-25 500 11 0.1 2.5 1500×780×1080 850 4
    5 GV-12/2-150 1000 12 0.2 15 1600×776×1080 900 5.5
    6 GV-400/20-60 3000 400 2 6 2600×1800×1700 3000 30
    7 GL-140/0.5-1.5 2000 140 0.05 0.15 2600×1800×1700 3000 15
    8 GL-150/0.3-5 2000 150 0.03 0.5 3230×1770×2200 3000 18.5
    9 GL-60/0.05-4 4000 60 0.005 0.4 2800×1600×1800 3000 22
    10 GD-255/1.2-28 6000 255 0.12 2.8 3600×2200×1800 6000 55
    11 GD-280/0.25-10 8000 280 0.025 1 3800×2300×2000 4000 75
    12 GD-450/1-12 9000 450 0.1 1.2 3800×2300×2000 4000 90
    The equipment size and weight are for reference only, and the final design shall prevail.
    Case Study
    Russia Case Study

    Russia

    United States Case Study

    United States

    Spain Case Study

    Spain

    Kazakhstan Case Study

    Kazakhstan

    Frequently Asked Questions
    Why is a diaphragm compressor preferred for compressing hydrogen chloride (HCl) gas?
    Diaphragm compressors feature a static sealing design that completely encloses the process gas inside the diaphragm head chamber. With no dynamic sealing points, it achieves safe zero leakage, which is critical for toxic and corrosive gases like hydrogen chloride.
    How does the compressor maintain ultra-high gas purity for electronic-grade applications?
    Throughout the compression cycle, the process gas only comes into contact with specially treated metal diaphragms and corrosion-resistant flow-wetted components. This prevents any contact with lubricating oil or sealing grease, making it ideal for producing high-purity HCl (purity > 99.999%) required in semiconductor processes.
    What materials are used to construct the flow-wetted components?
    Components such as the diaphragm chamber, cylinder head, gas valves, piping, and flanges are made from corrosion-resistant alloys. Standard configuration uses SS316L stainless steel to resist chloride pitting and stress corrosion cracking (SCC), while higher-grade nickel-based alloys can be selected for wet or harsh conditions.
    What happens if a diaphragm ruptures during compressor operation?
    The compressor is equipped with a diaphragm rupture alarm system. If the inner diaphragm fails, the system detects it immediately, triggers an alarm, and initiates a safe, automated shutdown to prevent gas leakage or oil contamination.
    What cooling methods are available for the GZ, GV, GL, and GD models?
    Depending on the specific model, installation environment, and operating requirements, both water-cooled and air-cooled methods are supported to maintain optimal operating temperatures.
    How is wet corrosion prevented inside the compressor system?
    The compressor skid integrates a high-efficiency inlet separator to remove liquid water and particulates. Controlling the moisture content at the inlet is key to preventing wet HCl corrosion. Additionally, exposed parts undergo specialized surface anti-corrosion treatments.