Company Information

* Company
* Name
* Phone

Key Parameters for Compressor inquiry

Suction Pressure

Discharge Pressure

Flow Rate

Cooling Method

Suction Temperature (℃)
Discharge Temperature(℃)
Power Supply(V/HZ)
Control Requirements
Gas Medium
Additional Remarks (You can also send your datasheet to our email)

High-Performance Chlorine Compressors from China Suppliers - Reliable Factory Solutions for Safe Chlor-Alkali Production

Introducing our cutting-edge solution for compressing severely toxic and strongly corrosive chlorine gas, designed by leading China suppliers. Our product features a core built with absolute sealing and corrosion-resistant materials, ensuring maximum safety and reliability. Utilizing advanced labyrinth seal technology (with nitrogen purge) or innovative liquid ring seal technology, it effectively eliminates leakage risks and withstands the harsh effects of chlorine and concentrated sulfuric acid, This equipment is specifically tailored to meet the rigorous demands of large-scale continuous production in the chlor-alkali industry. With exceptional fault tolerance for varying process parameters, including moisture content, it serves as essential core equipment for safe production. Trust our factory to deliver the highest standards in safety, reliability, and media adaptability for your industrial needs

    Chlorine Diaphragm Compressor Advantages

    • 01
      Absolutely Oil-Free & Zero Leakage Seal
      The "static seal" structure of the diaphragm compressor ensures that the gas is 100% free from contact with lubricating oil, fully meeting the "absolute oil-free" requirement for chlorine compression. Simultaneously, its embedded diaphragm head or combined oil distribution plate design significantly reduces sealing surfaces. Coupled with high-strength bolt pre-tightening, it achieves zero leakage containment of highly toxic chlorine, preventing the escape of poisonous gas that could harm personnel and the environment, and also preventing external moisture from entering the system and causing corrosion.
    • 02
      Ultra-High Gas Purity Maintenance & Active Safety Protection
      This structure absolutely guarantees that the purity of the compressed chlorine is free from any contamination. The standard three-layer diaphragm rupture alarm system is key to active safety. When any layer of the diaphragm experiences an anomaly, a pressure switch immediately triggers an audible and visual alarm and automatically initiates an interlock shutdown to prevent the incident from escalating. This characteristic makes it especially suitable for electronic-grade high-purity chlorine or chemical processes with stringent cleanliness requirements.

    Key Design Points for Chlorine Diaphragm Compressors

    • ⚙️

      Strict Distinction of Material Corrosion Resistance Based on Moisture Content

      Material selection is the decisive factor in chlorine compressor design. For dry chlorine with a moisture content strictly controlled to ≤ 0.05% (by weight), carbon steel may be considered for wetted parts. However, for the vast majority of operating conditions where moisture may be present, chlorine reacts with water to form hydrochloric acid, necessitating the use of high-grade corrosion-resistant alloys. Technical agreements typically mandate that all wetted metal parts be made of 316L stainless steel or higher grade materials, with special requirements for welding procedures and surface passivation treatment to address potential stress corrosion cracking induced by chloride ions.

    • 🛡️

      Integrated Safety Purge and Purging System

      Before startup, the compressor and the entire piping system must be thoroughly purged with high-purity nitrogen or inert gas to expel air and moisture, preventing the formation of explosive mixtures or corrosive environments. The design must integrate dedicated purge and vent connections and valve groups to ensure the operating procedures can be executed simply and reliably.

    • 📊

      Targeted Diaphragm Cavity and Monitoring Design

      The diaphragm must be made of a special alloy material resistant to chlorine corrosion. The diaphragm cavity profile needs to be optimized to extend diaphragm life. The system must be equipped with comprehensive temperature and pressure monitoring. The discharge temperature should be controlled within a safe range (typically well below the general limit of 180°C) through efficient inter-stage coolers, with over-limit alarms and shutdowns configured. All electrical instruments must meet an explosion-proof rating of at least Ex d IIB T4 to suit the potentially explosive environment.

    Certificates

    eac
    ce
    iso
    iso2033
    atex

    Model Selection

    Chlorine Diaphragm Compressor
    ModelG70Z/G95Z/G110Z/G130Z Piston Stroke70mm~130mm
    Maximum Piston Force10KN~30KN Maximum Discharge Pressure70Mpa
    Flow Range1~500Nm³/h Motor Power2.2KW~30KW
    Crankshaft Speed420rpm Cooling MethodWater Cooled/Air Cooled
    Cl2 Diaphragm Compressor
    ModelG70V/G95V/G130V Piston Stroke70mm~130mm
    Maximum Piston Force10KN~30KN Maximum Discharge Pressure50Mpa
    Flow Range1~200Nm³/h Motor Power2.2KW~30KW
    Crankshaft Speed420rpm Cooling MethodWater-cooled / Air-cooled
    High Purity Cl2 Diaphragm Compressor
    ModelG110L/G130L Piston Stroke110mm~130mm
    Maximum Piston Force20KN~40KN Maximum Discharge Pressure100Mpa
    Flow Range10~1000Nm³/h Motor Power7.5KW~90KW
    Crankshaft Speed420rpm Cooling MethodWater-cooled / Air-cooled
    Oil-Free Chlorine Diaphragm Compressor
    ModelG110D/G130D/G150D/G180D/G182D/G210D Piston Stroke110mm~210mm
    Maximum Piston Force20KN~160KN Maximum Discharge Pressure100Mpa
    Flow Range30~2000Nm³/h Motor Power22KW~200KW
    Crankshaft Speed420rpm Cooling MethodWater-cooled / Air-cooled
    G Diaphragm type compressor
    Z Piston stroke 70mm
    5 Flow (Nm³/h)
    6 Inlet pressure (barg)
    10 Outlet pressure (barg)
    No. Model Cooling water Flow Inlet pressure Outlet pressure Dimensions L×W×H Weight Motor Power
    (L/h) (Nm³/h) (MPa) (MPa) (≈mm) (≈kg) (kW)
    1 GZ-5/6-10 500 5 0.6 1 1200×700×1100 700 2.2
    2 GZ-7/0.1-6 500 7 0.01 0.6 1200×900×1200 800 3
    3 GZ-1/1.5-8 500 1 0.15 0.8 1200×900×1200 800 4
    4 GV-0.35/100 500 0.35 Atmospheric 10 1200×850×1200 1000 3
    5 GV-23/1 500 23 Atmospheric 0.1 1200×900×1250 900 5.5
    6 GV-70/5-10 1000 70 0.5 1 1200×900×1300 900 7.5
    7 GL-25/15 1000 25 Atmospheric 1.5 2200×1650×1450 3000 7.5
    8 GL-150/0.3-5 2000 150 0.03 0.5 3230×1770×2200 3000 18.5
    9 GL-170/2.5-18 2000 170 0.25 1.8 2900×2000×1700 3000 22
    10 GD-900/(2-6)-12 5000 900 0.2-0.6 1.2 3500×2300×1500 4500 45
    11 GD-600/1.5-5 5000 600 0.15 0.5 3500×2300×1800 4500 45
    12 GD-1306/(5-7)-12 8000 1306 0.5-0.7 1.2 3800×2300×1800 6000 75
    The equipment size and weight are for reference only, and the final design shall prevail.

    Case Study

    Russia Case

    Russia

    United States Case

    United States

    Spain Case

    Spain

    Kazakhstan Case

    Kazakhstan

    Frequently Asked Questions (FAQ)

    Q1: Why is a diaphragm compressor preferred for chlorine gas compression?

    A1: Diaphragm compressors feature a static seal design that guarantees 100% oil-free compression and zero gas leakage. This prevents highly toxic chlorine gas from escaping into the environment and protects the gas from oil contamination.

    Q2: How does moisture content affect the material selection of the compressor?

    A2: For dry chlorine (moisture ≤ 0.05%), carbon steel can be used. However, if any moisture is present, chlorine forms corrosive hydrochloric acid, requiring high-grade alloys like 316L stainless steel or superior corrosion-resistant materials for all wetted parts.

    Q3: What safety measures protect against diaphragm failure?

    A3: A standard three-layer diaphragm rupture alarm system is integrated. If any layer fails, a pressure switch immediately triggers visual/audible alarms and initiates an automatic interlock shutdown to prevent toxic leaks.

    Q4: Why is nitrogen purging necessary before startup?

    A4: Purging the compressor and piping with high-purity nitrogen removes air and moisture. This prevents the formation of explosive gas mixtures and stops the formation of corrosive hydrochloric acid inside the system.

    Q5: What are the cooling options for these compressors?

    A5: Depending on the specific model and process requirements, both water-cooled and air-cooled systems are available to keep discharge temperatures safely within operational limits.

    Q6: Are the electrical instruments safe for hazardous environments?

    A6: Yes, all electrical instruments and monitoring systems meet an explosion-proof rating of at least Ex d IIB T4, ensuring safe operation in potentially explosive environments.