Chlorine Compressor for Safe Production - Top China Suppliers & Factory with Corrosion-Resistant Technology
Chlorine Diaphragm Compressor Advantages
01
Absolutely Oil-Free & Zero Leakage Seal
The "static seal" structure of the diaphragm compressor ensures that the gas is 100% free from contact with lubricating oil, fully meeting the "absolute oil-free" requirement for chlorine compression. Simultaneously, its embedded diaphragm head or combined oil distribution plate design significantly reduces sealing surfaces. Coupled with high-strength bolt pre-tightening, it achieves zero leakage containment of highly toxic chlorine, preventing the escape of poisonous gas that could harm personnel and the environment, and also preventing external moisture from entering the system and causing corrosion.
02
Ultra-High Gas Purity Maintenance & Active Safety Protection
This structure absolutely guarantees that the purity of the compressed chlorine is free from any contamination. The standard three-layer diaphragm rupture alarm system is key to active safety. When any layer of the diaphragm experiences an anomaly, a pressure switch immediately triggers an audible and visual alarm and automatically initiates an interlock shutdown to prevent the incident from escalating. This characteristic makes it especially suitable for electronic-grade high-purity chlorine or chemical processes with stringent cleanliness requirements.
Key Design Points for Chlorine Diaphragm Compressors
01
Strict Distinction of Material Corrosion Resistance Based on Moisture Content
Material selection is the decisive factor in chlorine compressor design. For dry chlorine with a moisture content strictly controlled to ≤ 0.05% (by weight), carbon steel may be considered for wetted parts. However, for the vast majority of operating conditions where moisture may be present, chlorine reacts with water to form hydrochloric acid, necessitating the use of high-grade corrosion-resistant alloys. Technical agreements typically mandate that all wetted metal parts be made of 316L stainless steel or higher grade materials, with special requirements for welding procedures and surface passivation treatment to address potential stress corrosion cracking induced by chloride ions.
02
Integrated Safety Purge and Purging System
Before startup, the compressor and the entire piping system must be thoroughly purged with high-purity nitrogen or inert gas to expel air and moisture, preventing the formation of explosive mixtures or corrosive environments. The design must integrate dedicated purge and vent connections and valve groups to ensure the operating procedures can be executed simply and reliably.
03
Targeted Diaphragm Cavity and Monitoring Design
The diaphragm must be made of a special alloy material resistant to chlorine corrosion. The diaphragm cavity profile needs to be optimized to extend diaphragm life. The system must be equipped with comprehensive temperature and pressure monitoring. The discharge temperature should be controlled within a safe range (typically well below the general limit of 180°C) through efficient inter-stage coolers, with over-limit alarms and shutdowns configured. All electrical instruments must meet an explosion-proof rating of at least Ex d IIB T4 to suit the potentially explosive environment.
Certificates
Model Selection
| Model | G70Z/G95Z/G110Z/G130Z |
| Piston Stroke | 70mm~130mm |
| Maximum Piston Force | 10KN~30KN |
| Maximum Discharge Pressure | 70Mpa |
| Flow Range | 1~500Nm³/h |
| Motor Power | 2.2KW~30KW |
| Crankshaft Speed | 420rpm |
| Cooling Method | Water Cooled/Air Cooled |
| Model | G70V/G95V/G130V |
| Piston Stroke | 70mm~130mm |
| Maximum Piston Force | 10KN~30KN |
| Maximum Discharge Pressure | 50Mpa |
| Flow Range | 1~200Nm³/h |
| Motor Power | 2.2KW~30KW |
| Crankshaft Speed | 420rpm |
| Cooling Method | Water-cooled / Air-cooled |
| Model | G110L/G130L |
| Piston Stroke | 110mm~130mm |
| Maximum Piston Force | 20KN~40KN |
| Maximum Discharge Pressure | 100Mpa |
| Flow Range | 10~1000Nm³/h |
| Motor Power | 7.5KW~90KW |
| Crankshaft Speed | 420rpm |
| Cooling Method | Water-cooled / Air-cooled |
| Model | G110D/G130D/G150D/G180D/G182D/G210D |
| Piston Stroke | 110mm~210mm |
| Maximum Piston Force | 20KN~160KN |
| Maximum Discharge Pressure | 100Mpa |
| Flow Range | 30~2000Nm³/h |
| Motor Power | 22KW~200KW |
| Crankshaft Speed | 420rpm |
| Cooling Method | Water-cooled / Air-cooled |
G
Diaphragm type compressor
Z
Piston stroke 70mm
5
Flow(Nm3/h)
6
Inlet pressure(barg)
10
Outlet pressure(barg)
| No. | Model | Cooling water | Flow | Inlet pressure | Outlet pressure | Dimensions L×W×H | Weight | Motor Power |
|---|---|---|---|---|---|---|---|---|
| (L/h) | (Nm³/h) | (MPa) | (MPa) | (≈mm) | (≈kg) | (kW) | ||
| 1 | GZ-5/6-10 | 500 | 5 | 0.6 | 1 | 1200×700×1100 | 700 | 2.2 |
| 2 | GZ-7/0.1-6 | 500 | 7 | 0.01 | 0.6 | 1200×900×1200 | 800 | 3 |
| 3 | GZ-1/1.5-8 | 500 | 1 | 0.15 | 0.8 | 1200×900×1200 | 800 | 4 |
| 4 | GV-0.35/100 | 500 | 0.35 | Atmospheric | 10 | 1200×850×1200 | 1000 | 3 |
| 5 | GV-23/1 | 500 | 23 | Atmospheric | 0.1 | 1200×900×1250 | 900 | 5.5 |
| 6 | GV-70/5-10 | 1000 | 70 | 0.5 | 1 | 1200×900×1300 | 900 | 7.5 |
| 7 | GL-25/15 | 1000 | 25 | Atmospheric | 1.5 | 2200×1650×1450 | 3000 | 7.5 |
| 8 | GL-150/0.3-5 | 2000 | 150 | 0.03 | 0.5 | 3230×1770×2200 | 3000 | 18.5 |
| 9 | GL-170/2.5-18 | 2000 | 170 | 0.25 | 1.8 | 2900×2000×1700 | 3000 | 22 |
| 10 | GD-900/(2-6)-12 | 5000 | 900 | 0.2-0.6 | 1.2 | 3500×2300×1500 | 4500 | 45 |
| 11 | GD-600/1.5-5 | 5000 | 600 | 0.15 | 0.5 | 3500×2300×1800 | 4500 | 45 |
| 12 | GD-1306/(5-7)-12 | 8000 | 1306 | 0.5-0.7 | 1.2 | 3800×2300×1800 | 6000 | 75 |
The equipment size and weight are for reference only, and the final design shall prevail.
Case Study
Frequently Asked Questions
Why is a diaphragm compressor considered absolutely oil-free?
The static seal structure of the diaphragm compressor keeps the compressed gas 100% separated from the lubricating oil. This completely satisfies the strict oil-free requirements necessary for compressing chlorine safely and without contamination.
How does the compressor achieve a zero-leakage containment of chlorine?
It features an embedded diaphragm head or combined oil distribution plate design that reduces overall sealing surfaces. Combined with high-strength bolt pre-tightening, it creates a secure seal that prevents toxic chlorine leaks and guards against external moisture entering the system.
What happens if a diaphragm ruptures during compressor operation?
The compressor is equipped with a standard three-layer diaphragm rupture alarm system. If any layer fails, a pressure switch instantly triggers audio-visual alarms and automatically shuts down the system via an interlock mechanism to prevent further damage.
How does chlorine moisture content affect the materials used in the compressor?
Dry chlorine (moisture content ≤ 0.05% by weight) allows the use of carbon steel for wetted parts. However, if moisture is present, chlorine forms corrosive hydrochloric acid, requiring high-grade alloys like 316L stainless steel or higher, along with special surface passivation.
Why is a safety purge system required before starting the compressor?
Purging the compressor and piping with high-purity nitrogen or inert gas is essential to expel air and moisture. This prevents the formation of explosive gas mixtures and blocks corrosive reactions inside the system before startup.
What safety and explosion-proof standards do these compressors follow?
Discharge temperatures are strictly controlled well below 180°C using inter-stage coolers. Additionally, all electrical instruments and components must adhere to an explosion-proof rating of at least Ex d IIB T4 to safely operate in hazardous environments.