Introducing our state-of-the-art chlorine gas compressor, expertly designed for handling severely toxic and highly corrosive chlorine gas. Manufactured in China, our product features a core built from absolute sealing and corrosion-resistant materials, ensuring unparalleled safety and reliability. Utilizing advanced labyrinth seal technology with nitrogen purge or liquid ring seal systems, this compressor effectively eliminates any leakage risks while resisting corrosion from chlorine and other harsh substances, such as concentrated sulfuric acid. As a leading supplier in the industry, we prioritize extreme safety and adaptability for various media. This compressor is essential for large-scale continuous production in the chlor-alkali sector, demonstrating exceptional fault tolerance for process parameters like moisture content. Trust our factory to deliver the core equipment your operation needs for safe and efficient production.

,

    Chlorine Diaphragm Compressor Advantages

    01

    Absolutely Oil-Free & Zero Leakage Seal

    The "static seal" structure of the diaphragm compressor ensures that the gas is 100% free from contact with lubricating oil, fully meeting the "absolute oil-free" requirement for chlorine compression. Simultaneously, its embedded diaphragm head or combined oil distribution plate design significantly reduces sealing surfaces. Coupled with high-strength bolt pre-tightening, it achieves zero leakage containment of highly toxic chlorine, preventing the escape of poisonous gas that could harm personnel and the environment, and also preventing external moisture from entering the system and causing corrosion.
    02

    Ultra-High Gas Purity Maintenance & Active Safety Protection

    This structure absolutely guarantees that the purity of the compressed chlorine is free from any contamination. The standard three-layer diaphragm rupture alarm system is key to active safety. When any layer of the diaphragm experiences an anomaly, a pressure switch immediately triggers an audible and visual alarm and automatically initiates an interlock shutdown to prevent the incident from escalating. This characteristic makes it especially suitable for electronic-grade high-purity chlorine or chemical processes with stringent cleanliness requirements.

    Key Design Points for Chlorine Diaphragm Compressors

    01

    Strict Distinction of Material Corrosion Resistance Based on Moisture Content

    Material selection is the decisive factor in chlorine compressor design. For dry chlorine with a moisture content strictly controlled to ≤ 0.05% (by weight), carbon steel may be considered for wetted parts. However, for the vast majority of operating conditions where moisture may be present, chlorine reacts with water to form hydrochloric acid, necessitating the use of high-grade corrosion-resistant alloys. Technical agreements typically mandate that all wetted metal parts be made of 316L stainless steel or higher grade materials, with special requirements for welding procedures and surface passivation treatment to address potential stress corrosion cracking induced by chloride ions.
    02

    Integrated Safety Purge and Purging System

    Before startup, the compressor and the entire piping system must be thoroughly purged with high-purity nitrogen or inert gas to expel air and moisture, preventing the formation of explosive mixtures or corrosive environments. The design must integrate dedicated purge and vent connections and valve groups to ensure the operating procedures can be executed simply and reliably.
    03

    Targeted Diaphragm Cavity and Monitoring Design

    The diaphragm must be made of a special alloy material resistant to chlorine corrosion. The diaphragm cavity profile needs to be optimized to extend diaphragm life. The system must be equipped with comprehensive temperature and pressure monitoring. The discharge temperature should be controlled within a safe range (typically well below the general limit of 180°C) through efficient inter-stage coolers, with over-limit alarms and shutdowns configured. All electrical instruments must meet an explosion-proof rating of at least Ex d IIB T4 to suit the potentially explosive environment.

    Certificates

    eac certificate
    ce certificate
    iso certificate
    iso2033 certificate
    atex certificate

    Model Selection

    Chlorine Diaphragm Compressor GZ
    Model G70Z/G95Z/G110Z/G130Z
    Piston Stroke 70mm~130mm
    Maximum Piston Force 10KN~30KN
    Maximum Discharge Pressure 70Mpa
    Flow Range 1~500Nm³/h
    Motor Power 2.2KW~30KW
    Crankshaft Speed 420rpm
    Cooling Method Water Cooled/Air Cooled
    Cl2 Diaphragm Compressor GV
    Model G70V/G95V/G130V
    Piston Stroke 70mm~130mm
    Maximum Piston Force 10KN~30KN
    Maximum Discharge Pressure 50Mpa
    Flow Range 1~200Nm³/h
    Motor Power 2.2KW~30KW
    Crankshaft Speed 420rpm
    Cooling Method Water-cooled / Air-cooled
    High Purity Cl2 Diaphragm Compressor GL
    Model G110L/G130L
    Piston Stroke 110mm~130mm
    Maximum Piston Force 20KN~40KN
    Maximum Discharge Pressure 100Mpa
    Flow Range 10~1000Nm³/h
    Motor Power 7.5KW~90KW
    Crankshaft Speed 420rpm
    Cooling Method Water-cooled / Air-cooled
    Oil-Free Chlorine Diaphragm Compressor GD
    Model G110D/G130D/G150D/G180D/G182D/G210D
    Piston Stroke 110mm~210mm
    Maximum Piston Force 20KN~160KN
    Maximum Discharge Pressure 100Mpa
    Flow Range 30~2000Nm³/h
    Motor Power 22KW~200KW
    Crankshaft Speed 420rpm
    Cooling Method Water-cooled / Air-cooled
    G
    Diaphragm type compressor
    Z
    Piston stroke 70mm
    5
    Flow(Nm3/h)
    6
    Inlet pressure(barg)
    10
    Outlet pressure(barg)
    No. Model Cooling water Flow Inlet pressure Outlet pressure Dimensions L×W×H Weight Motor Power
    (L/h) (Nm³/h) (MPa) (MPa) (≈mm) (≈kg) (kW)
    1 GZ-5/6-10 500 5 0.6 1 1200×700×1100 700 2.2
    2 GZ-7/0.1-6 500 7 0.01 0.6 1200×900×1200 800 3
    3 GZ-1/1.5-8 500 1 0.15 0.8 1200×900×1200 800 4
    4 GV-0.35/100 500 0.35 Atmospheric 10 1200×850×1200 1000 3
    5 GV-23/1 500 23 Atmospheric 0.1 1200×900×1250 900 5.5
    6 GV-70/5-10 1000 70 0.5 1 1200×900×1300 900 7.5
    7 GL-25/15 1000 25 Atmospheric 1.5 2200×1650×1450 3000 7.5
    8 GL-150/0.3-5 2000 150 0.03 0.5 3230×1770×2200 3000 18.5
    9 GL-170/2.5-18 2000 170 0.25 1.8 2900×2000×1700 3000 22
    10 GD-900/(2-6)-12 5000 900 0.2-0.6 1.2 3500×2300×1500 4500 45
    11 GD-600/1.5-5 5000 600 0.15 0.5 3500×2300×1800 4500 45
    12 GD-1306/(5-7)-12 8000 1306 0.5-0.7 1.2 3800×2300×1800 6000 75
    The equipment size and weight are for reference only, and the final design shall prevail.

    Case Study

    Project in Russia
    Russia
    Project in United States
    United States
    Project in Spain
    Spain
    Project in Kazakhstan
    Kazakhstan

    Frequently Asked Questions

    Why is a diaphragm compressor considered absolutely oil-free?
    The static seal structure of the diaphragm compressor keeps the compressed gas 100% separated from the lubricating oil. This completely satisfies the strict oil-free requirements necessary for compressing chlorine safely and without contamination.
    How does the compressor achieve a zero-leakage containment of chlorine?
    It features an embedded diaphragm head or combined oil distribution plate design that reduces overall sealing surfaces. Combined with high-strength bolt pre-tightening, it creates a secure seal that prevents toxic chlorine leaks and guards against external moisture entering the system.
    What happens if a diaphragm ruptures during compressor operation?
    The compressor is equipped with a standard three-layer diaphragm rupture alarm system. If any layer fails, a pressure switch instantly triggers audio-visual alarms and automatically shuts down the system via an interlock mechanism to prevent further damage.
    How does chlorine moisture content affect the materials used in the compressor?
    Dry chlorine (moisture content ≤ 0.05% by weight) allows the use of carbon steel for wetted parts. However, if moisture is present, chlorine forms corrosive hydrochloric acid, requiring high-grade alloys like 316L stainless steel or higher, along with special surface passivation.
    Why is a safety purge system required before starting the compressor?
    Purging the compressor and piping with high-purity nitrogen or inert gas is essential to expel air and moisture. This prevents the formation of explosive gas mixtures and blocks corrosive reactions inside the system before startup.
    What safety and explosion-proof standards do these compressors follow?
    Discharge temperatures are strictly controlled well below 180°C using inter-stage coolers. Additionally, all electrical instruments and components must adhere to an explosion-proof rating of at least Ex d IIB T4 to safely operate in hazardous environments.