Company Information

* Company
* Name
* Phone

Key Parameters for Compressor inquiry

Suction Pressure

Discharge Pressure

Flow Rate

Cooling Method

Suction Temperature (℃)
Discharge Temperature(℃)
Power Supply(V/HZ)
Control Requirements
Gas Medium
Additional Remarks (You can also send your datasheet to our email)

Chlorine Compressor Factory in China - Reliable Suppliers for Safe and Corrosion-Resistant Chlorine Gas Compression Solutions

Introducing our state-of-the-art solution for compressing highly toxic and corrosive chlorine gas, specifically designed for the chlor-alkali industry. Our factory in China utilizes advanced sealing technologies, including labyrinth seals with nitrogen purge and liquid ring seals, to ensure absolute protection against leakage. These corrosion-resistant materials are engineered to withstand harsh environments, including concentrated sulfuric acid, offering unparalleled safety and reliability. As a leading supplier, we cater to large-scale continuous production needs, providing exceptional fault tolerance for various process parameters such as moisture content. Trust our equipment to be the core of your safe production operations in the chlor-alkali sector.

    Chlorine Diaphragm Compressor Advantages

    01

    Absolutely Oil-Free & Zero Leakage Seal

    The "static seal" structure of the diaphragm compressor ensures that the gas is 100% free from contact with lubricating oil, fully meeting the "absolute oil-free" requirement for chlorine compression. Simultaneously, its embedded diaphragm head or combined oil distribution plate design significantly reduces sealing surfaces. Coupled with high-strength bolt pre-tightening, it achieves zero leakage containment of highly toxic chlorine, preventing the escape of poisonous gas that could harm personnel and the environment, and also preventing external moisture from entering the system and causing corrosion.

    02

    Ultra-High Gas Purity Maintenance & Active Safety Protection

    This structure absolutely guarantees that the purity of the compressed chlorine is free from any contamination. The standard three-layer diaphragm rupture alarm system is key to active safety. When any layer of the diaphragm experiences an anomaly, a pressure switch immediately triggers an audible and visual alarm and automatically initiates an interlock shutdown to prevent the incident from escalating. This characteristic makes it especially suitable for electronic-grade high-purity chlorine or chemical processes with stringent cleanliness requirements.

    Key Design Points for Chlorine Diaphragm Compressors

    01

    Strict Distinction of Material Corrosion Resistance Based on Moisture Content

    Material selection is the decisive factor in chlorine compressor design. For dry chlorine with a moisture content strictly controlled to ≤ 0.05% (by weight), carbon steel may be considered for wetted parts. However, for the vast majority of operating conditions where moisture may be present, chlorine reacts with water to form hydrochloric acid, necessitating the use of high-grade corrosion-resistant alloys. Technical agreements typically mandate that all wetted metal parts be made of 316L stainless steel or higher grade materials, with special requirements for welding procedures and surface passivation treatment to address potential stress corrosion cracking induced by chloride ions.

    02

    Integrated Safety Purge and Purging System

    Before startup, the compressor and the entire piping system must be thoroughly purged with high-purity nitrogen or inert gas to expel air and moisture, preventing the formation of explosive mixtures or corrosive environments. The design must integrate dedicated purge and vent connections and valve groups to ensure the operating procedures can be executed simply and reliably.

    03

    Targeted Diaphragm Cavity and Monitoring Design

    The diaphragm must be made of a special alloy material resistant to chlorine corrosion. The diaphragm cavity profile needs to be optimized to extend diaphragm life. The system must be equipped with comprehensive temperature and pressure monitoring. The discharge temperature should be controlled within a safe range (typically well below the general limit of 180°C) through efficient inter-stage coolers, with over-limit alarms and shutdowns configured. All electrical instruments must meet an explosion-proof rating of at least Ex d IIB T4 to suit the potentially explosive environment.

    International Certification & Standards

    EAC Certificate
    CE Certificate
    ISO Certification
    ISO Standard
    ATEX Explosion-Proof Certification

    Model Selection & Series Specifications

    Chlorine Diaphragm Compressor GZ Series
    GZ Series
    Models:G70Z / G95Z / G110Z / G130Z
    Piston Stroke:70mm ~ 130mm
    Piston Force:10KN ~ 30KN
    Max Pressure:70 MPa
    Flow Range:1 ~ 500 Nm³/h
    Motor Power:2.2 kW ~ 30 kW
    Cooling:Water / Air Cooled
    Cl2 Diaphragm Compressor GV Series
    GV Series
    Models:G70V / G95V / G130V
    Piston Stroke:70mm ~ 130mm
    Piston Force:10KN ~ 30KN
    Max Pressure:50 MPa
    Flow Range:1 ~ 200 Nm³/h
    Motor Power:2.2 kW ~ 30 kW
    Cooling:Water / Air Cooled
    High Purity Cl2 Diaphragm Compressor GL Series
    GL Series
    Models:G110L / G130L
    Piston Stroke:110mm ~ 130mm
    Piston Force:20KN ~ 40KN
    Max Pressure:100 MPa
    Flow Range:10 ~ 1000 Nm³/h
    Motor Power:7.5 kW ~ 90 kW
    Cooling:Water / Air Cooled
    Oil-Free Chlorine Diaphragm Compressor GD Series
    GD Series
    Models:G110D ~ G210D
    Piston Stroke:110mm ~ 210mm
    Piston Force:20KN ~ 160KN
    Max Pressure:100 MPa
    Flow Range:30 ~ 2000 Nm³/h
    Motor Power:22 kW ~ 200 kW
    Cooling:Water / Air Cooled
    Model Nomenclature Explanation (e.g., GZ-5/6-10):
    G Diaphragm type compressor
    Z Piston stroke 70mm
    5 Flow capacity (Nm³/h)
    6 Inlet pressure (barg)
    10 Outlet pressure (barg)
    No. Model Cooling Water Flow Inlet Pressure Outlet Pressure Dimensions (L×W×H) Weight Motor Power
    (L/h) (Nm³/h) (MPa) (MPa) (≈mm) (≈kg) (kW)
    1 GZ-5/6-10 500 5 0.6 1.0 1200×700×1100 700 2.2
    2 GZ-7/0.1-6 500 7 0.01 0.6 1200×900×1200 800 3.0
    3 GZ-1/1.5-8 500 1 0.15 0.8 1200×900×1200 800 4.0
    4 GV-0.35/100 500 0.35 Atmospheric 10.0 1200×850×1200 1000 3.0
    5 GV-23/1 500 23 Atmospheric 0.1 1200×900×1250 900 5.5
    6 GV-70/5-10 1000 70 0.5 1.0 1200×900×1300 900 7.5
    7 GL-25/15 1000 25 Atmospheric 1.5 2200×1650×1450 3000 7.5
    8 GL-150/0.3-5 2000 150 0.03 0.5 3230×1770×2200 3000 18.5
    9 GL-170/2.5-18 2000 170 0.25 1.8 2900×2000×1700 3000 22.0
    10 GD-900/(2-6)-12 5000 900 0.2-0.6 1.2 3500×2300×1500 4500 45.0
    11 GD-600/1.5-5 5000 600 0.15 0.5 3500×2300×1800 4500 45.0
    12 GD-1306/(5-7)-12 8000 1306 0.5-0.7 1.2 3800×2300×1800 6000 75.0
    * Equipment dimensions and weights are for engineering reference only; customized final design drawings shall prevail.

    Global Project Case Studies

    Chlorine Compressor Project in Russia

    Russia

    Chlorine Gas Compressor System United States

    United States

    Industrial Compressor Application Spain

    Spain

    High Pressure Gas Compression Kazakhstan

    Kazakhstan

    Frequently Asked Questions (FAQ)

    Why is a diaphragm compressor the preferred choice for chlorine gas compression?

    A diaphragm compressor provides a completely static seal separating the hydraulic oil from the process gas. This eliminates any risk of lubricating oil contamination, ensures 100% oil-free compression, and guarantees zero leakage of toxic chlorine into the environment.

    How do material requirements differ between dry and wet chlorine compression?

    For dry chlorine (moisture content ≤ 0.05% by weight), carbon steel can be utilized for wetted parts. However, if moisture is present, chlorine forms corrosive hydrochloric acid, requiring high-grade corrosion-resistant alloys such as 316L stainless steel, special surface passivation, and dedicated welding procedures to avoid stress corrosion cracking.

    How does the triple-diaphragm rupture alarm system work?

    The compressor is equipped with a three-layer diaphragm structure. If any layer develops an anomaly or micro-fracture, an integrated pressure sensor detects the pressure variance between layers, immediately triggering an audible/visual alarm and an automated safety interlock shutdown before any external leak occurs.

    Why is nitrogen purging essential before compressor startup?

    Thorough purging with high-purity nitrogen or inert gas evacuates atmospheric air and ambient moisture from the piping and compression chamber. This critical safety step prevents moisture-induced hydrochloric acid corrosion and avoids hazardous explosive mixtures.

    What cooling and explosion-proof specifications are applied?

    Both air-cooled and water-cooled configurations are supported with inter-stage cooling to maintain discharge temperatures well below 180°C. All integrated electrical instruments and motors meet an explosion-proof rating of at least Ex d IIB T4 and comply with CE, EAC, and ATEX standards.