China Hydrogen Chloride Compressor Factory: Suppliers of High-Purity Equipment for Corrosive Gas Management
Absolute Sealing, Safe Zero Leakage
The static sealing design completely encloses the gas within the diaphragm head chamber without any dynamic sealing points, fundamentally achieving zero leakage of hydrogen chloride gas. This greatly ensures operator safety and environmental friendliness, meeting the most stringent environmental and safety regulations.
Ultra-High Gas Purity, No Contamination
During the entire compression process, the process gas only contacts specially treated metal diaphragms and corrosion-resistant flow-wetted components, completely avoiding contamination from lubricating oil or sealing grease. This characteristic makes it ideal equipment for producing electronic-grade high-purity hydrogen chloride (purity > 99.999%) used in semiconductor etching processes, ensuring the quality of end products.
Full Corrosion-Resistant Materials for Diaphragm Head and Flow-Wetted Parts
All metal components in contact with hydrogen chloride, including the diaphragm chamber, cylinder head, gas valves, inlet/outlet piping, and flanges, must be made of corrosion-resistant alloys. The standard configuration is SS316L stainless steel, whose addition of molybdenum (Mo) significantly enhances resistance to chloride pitting and stress corrosion cracking (SCC). For applications with extremely high moisture content or harsh operating conditions, evaluation and selection of higher-grade nickel-based alloys are required.
Diaphragm Material and Structural Reliability
As the core isolation component, the diaphragm must be made of a special alloy with excellent resistance to hydrogen chloride corrosion and high fatigue strength, such as Inconel 718. Advanced designs such as an embedded diaphragm head should be adopted structurally to simplify the sealing surfaces, reduce potential leakage points, and ensure sufficient cycle life. A diaphragm rupture alarm device must be provided; once the inner diaphragm is damaged, the system can promptly alarm and shut down safely.
Integrated Safety and Monitoring System
The compressor skid integrates a high-efficiency inlet separator to strictly remove liquid water and particulates from the gas. Controlling the inlet moisture content is key to preventing wet corrosion. All exposed parts shall undergo surface anti-corrosion treatment to resist atmospheric corrosion. The system is equipped with comprehensive monitoring of pressure, temperature, and oil pressure, along with interlock shutdown functions to ensure safe operation within set parameters.
| ModelG70Z / G95Z / G110Z / G130Z | Piston Stroke70mm ~ 130mm |
| Max Piston Force10KN ~ 30KN | Max Discharge Pressure70 MPa |
| Flow Range1 ~ 500 Nm³/h | Motor Power2.2KW ~ 30KW |
| Crankshaft Speed420 rpm | Cooling MethodWater / Air Cooled |
| ModelG70V / G95V / G130V | Piston Stroke70mm ~ 130mm |
| Max Piston Force10KN ~ 30KN | Max Discharge Pressure50 MPa |
| Flow Range1 ~ 200 Nm³/h | Motor Power2.2KW ~ 30KW |
| Crankshaft Speed420 rpm | Cooling MethodWater / Air Cooled |
| ModelG110L / G130L | Piston Stroke110mm ~ 130mm |
| Max Piston Force20KN ~ 40KN | Max Discharge Pressure100 MPa |
| Flow Range10 ~ 1000 Nm³/h | Motor Power7.5KW ~ 90KW |
| Crankshaft Speed420 rpm | Cooling MethodWater / Air Cooled |
| ModelG110D / G130D / G150D / G180D / G210D | Piston Stroke110mm ~ 210mm |
| Max Piston Force20KN ~ 160KN | Max Discharge Pressure100 MPa |
| Flow Range30 ~ 2000 Nm³/h | Motor Power22KW ~ 200KW |
| Crankshaft Speed420 rpm | Cooling MethodWater / Air Cooled |
| No. | Model | Cooling water | Flow | Inlet pressure | Outlet pressure | Dimensions L×W×H | Weight | Motor Power |
|---|---|---|---|---|---|---|---|---|
| (L/h) | (Nm³/h) | (MPa) | (MPa) | (≈mm) | (≈kg) | (kW) | ||
| 1 | GZ-5/0.5-8 | 500 | 5 | 0.05 | 0.8 | 1400×740×1240 | 700 | 2.2 |
| 2 | GZ-14/39-45 | 500 | 14 | 3.9 | 4.5 | 1000×460×1100 | 700 | 2.2 |
| 3 | GZ-60/30-40 | 500 | 60 | 3 | 4 | 1400×800×1300 | 750 | 3 |
| 4 | GV-11/1-25 | 500 | 11 | 0.1 | 2.5 | 1500×780×1080 | 850 | 4 |
| 5 | GV-12/2-150 | 1000 | 12 | 0.2 | 15 | 1600×776×1080 | 900 | 5.5 |
| 6 | GV-400/20-60 | 3000 | 400 | 2 | 6 | 2600×1800×1700 | 3000 | 30 |
| 7 | GL-140/0.5-1.5 | 2000 | 140 | 0.05 | 0.15 | 2600×1800×1700 | 3000 | 15 |
| 8 | GL-150/0.3-5 | 2000 | 150 | 0.03 | 0.5 | 3230×1770×2200 | 3000 | 18.5 |
| 9 | GL-60/0.05-4 | 4000 | 60 | 0.005 | 0.4 | 2800×1600×1800 | 3000 | 22 |
| 10 | GD-255/1.2-28 | 6000 | 255 | 0.12 | 2.8 | 3600×2200×1800 | 6000 | 55 |
| 11 | GD-280/0.25-10 | 8000 | 280 | 0.025 | 1 | 3800×2300×2000 | 4000 | 75 |
| 12 | GD-450/1-12 | 9000 | 450 | 0.1 | 1.2 | 3800×2300×2000 | 4000 | 90 |
A diaphragm compressor utilizes a static sealing design with zero dynamic seal points, eliminating external gas leakage. Furthermore, the gas cavity is fully isolated from lubricating oil, ensuring ultra-pure, contamination-free gas transfer ideal for toxic, corrosive, and high-purity applications.
Standard flow-wetted components and gas heads utilize SS316L stainless steel enriched with molybdenum for resistance against chloride pitting and stress corrosion cracking. For core diaphragms, high fatigue strength alloys like Inconel 718 or premium nickel-based alloys are configured.
Yes. Because the process gas only contacts specially treated corrosion-resistant metal surfaces with zero oil lubrication in the gas chamber, purity levels exceeding 99.999% can be safely preserved for semiconductor etching and microelectronics processes.
The compressor features an integrated multi-layer diaphragm rupture alarm device. If any diaphragm layer encounters damage, the safety monitoring system detects pressure deviation instantly, triggers an alarm, and executes an automated interlock shutdown.
Dry HCl gas is significantly less corrosive than moist HCl. The integrated skid includes a high-efficiency inlet separator to eliminate moisture and particulate carryover, strictly protecting internal valves and diaphragm chambers from aggressive wet acid corrosion.
Both water-cooled and air-cooled options are available across the GZ, GV, GL, and GD series, with customizable discharge pressures up to 100 MPa and flow capacities from 1 to 2000 Nm³/h tailored to specific process conditions.